This is the original submission, which is not
the current revision.
This display is available for archival purposes.
PROJECT 1320:
2421 Darwin Rd
| Submitted by: | JSD Professional Services, Inc. |
| Project type: | Permitted Use |
| Description: | DNR boat storage building |
| Status: | completed on 7/23/2009 |
Project has been completed.
| Agency | Status | Requirements | Remarks | Checkout Date | Reviewed |
| Zoning | approved | | | 2/23/2009 | 2/24/2009 |
| Traffic Engineering | approved | | | 2/18/2009 | 2/20/2009 |
| Fire | denied | 1 2 3 4 5 | | 2/20/2009 | 2/20/2009 |
| Engineering | supplement needed | 1 2 | 3 | 2/20/2009 | 2/24/2009 |
| Planning | approved | | | 2/25/2009 | 2/25/2009 |
| Urban Design Commission | approved | | | 2/20/2009 | 2/20/2009 |
| Engineering Mapping | supplement needed | 1 | 2 | 2/24/2009 | 2/27/2009 |
| Revision | Submit date |
| original | 2/18/2009 |
| 1 | 4/13/2009 |
Engineering
Supplementary material required:
This site will disturb 4,000 sf or more of land area and require an Erosion Control Permit. Please submit an Erosion Control and Storm Water Management Permit Application for approval.
Supplementary material required:
Submit plan sheets in pdf format to jbenedict@cityofmadison.com.
Note:
Supplementary Condition Completed (was The applicant shall demonstrate compliance with Section 37.07 and 37.08 of the Madison General Ordinances regarding permissible soil loss rates. The erosion control plan shall include Universal Soil Loss Equation (USLE) computations for the construction period. Measures shall be implemented in order to maintain a soil loss rate below 7.5-tons per acre per year.)
Top
Engineering Mapping
Supplementary material required:
The Applicant shall submit, prior to plan sign-off, a digital CAD file (single file) to the Engineering Program Specialist in the Engineering Division (Lori Zenchenko). The digital CAD file shall be to scale and represent final construction. The single CAD file submittal can be either AutoCAD (dwg) Version 2001 or older, MicroStation (dgn) Version J or older, or Universal (dxf) format and contain the only the following data, each on a separate layer name/level number: a) Building Footprints; b) Internal Walkway Areas; c) Internal Site Parking Areas; d) Other Miscellaneous Impervious Areas (i.e. gravel, crushed stone, bituminous/asphalt, concrete, etc.); e) Right-of-Way lines (public and private); f) All Underlying Lot lines or parcel lines if unplatted; g) Lot numbers or the words “unplatted”; h) Lot/Plat dimensions; i) Street names. All other levels (contours, elevations, etc) are not to be included with this file submittal. NOTE: Email file transmissions preferred Lzenchenko@cityofmadison.com . Include the site address in the subject line of this transmittal. Any changes or additions to the location of the building, sidewalks, parking/pavement during construction will require a new CAD file.
Note:
The City of Madison Engineering Division approved address for the proposed boat storage building will be 2429 Darwin Road.
Top
Fire
Redraft required:
Provide a completed MFD "Fire Apparatus Access and Fire Hydrant Worksheet" with the site plan submittal.
Redraft required:
The revised site plans shall clearly identify the location of all fire lanes.
Redraft required:
Provide a fire lane that extends to within 150-feet of all exterior portions of the structure.
Redraft required:
A dead-end fire lane that is longer than 150-feet shall terminate in a turnaround. Provide an approved turnaround (cul-de-sac, 45 degree wye, 90 degree tee) at the end of a fire lane that is more than 150-feet in length.
Redraft required:
All portions of the exterior walls of newly constructed public buildings and places of employment and open storage of combustible materials shall be within 500-feet of at least TWO fire hydrants. Distances are measured along the path traveled by the fire truck as the hose lay’s off the truck. See MGO 34.20 for additional information.
Top