PROJECT 1354: 4802 Annamark Dr

Submitted by:KFC
Project type:Minor Alteration to CU
Description:facade change triggering parking lot review
Status:completed on 7/6/2009

Project has been completed.

AgencyStatusRequirementsRemarksCheckout DateReviewed
Zoningapproved 1  2  3  4  54/3/20094/6/2009
Traffic Engineeringapproved 1  24/1/20094/1/2009
Fireapproved  4/2/20094/2/2009
Engineeringapproved 1  24/2/20094/3/2009
Planningapproved 14/16/20094/16/2009
Engineering Mappingapproved 1  24/3/20094/6/2009

RevisionSubmit date
original3/31/2009


Engineering 

Note: No land disturbance or changes proposed to the site layout. No erosion control or stormwater management permit requirements for this project.

Note: Supplementary Condition Completed (was Submit PDF's of the site plan for Engineering records. File(s) can be emailed to Tim Troester at ttroester@cityofmadison.com)

Top
Engineering Mapping 

Note: Supplementary Condition Completed (was The Applicant shall submit, prior to plan sign-off, a digital CAD file (single file) to the Engineering Program Specialist in the Engineering Division (Lori Zenchenko). The digital CAD file shall be to scale and represent final construction. The single CAD file submittal can be either AutoCAD (dwg) Version 2001 or older, MicroStation (dgn) Version J or older, or Universal (dxf) format and contain the only the following data, each on a separate layer name/level number: a) Building Footprints; b) Internal Walkway Areas; c) Internal Site Parking Areas; d) Other Miscellaneous Impervious Areas (i.e. gravel, crushed stone, bituminous/asphalt, concrete, etc.); e) Right-of-Way lines (public and private); f) All Underlying Lot lines or parcel lines if unplatted; g) Lot numbers or the words “unplatted”; h) Lot/Plat dimensions; i) Street names. All other levels (contours, elevations, etc) are not to be included with this file submittal. NOTE: Email file transmissions preferred Lzenchenko@cityofmadison.com . Include the site address in the subject line of this transmittal. Any changes or additions to the location of the building, sidewalks, parking/pavement during construction will require a new CAD file.)

Note: Supplementary Condition Completed (was CAD file should include the correct parcel boundary bearings and be drawn to scale. The metes & bounds on the plan do not close; there are errors on the north boundary line and also along Annamark Drive. REGIONAL EAST, PART OF LOTS 10 & 11, PRT DESC AS FOL, COM AT MOST NLY COR SD LOT 11, TH S 28 DEG 07 MIN 42 SEC E 108.48 FT TO POB, TH CONT SD BRG 55 FT TO PT OF CUR, TH ON CUR TO LEFT, RAD 897.37 FT, CHRS BRS S 34 DEG 17 MIN 58 SEC E 192.93 FT TO PT OF REVERSE CUR, TH ON CUR TO RIGHT, RAD 25 FT, CHRS BRS S 04 DEG 31 MIN 46 SEC W 35.36 FT, TH S 49 DEG 31 MIN 46 SEC W 17 FT TO PT OF CUR, TH ON CUR TO RIGHT, RAD 450 FT, CHRD BRS S 60 DEG 05 MIN 38 SEC W 165.01 FT, TH N 19 DEG 20 MIN 30 SEC W 200.04 FT, TH N 46 DEG 10 MIN 20 SEC W 92.17 FT, TH N 61 DEG 52 MIN 18 SEC E 177.87 FT TO POB. )

Top

Planning 

Note: The painting of the brick at the base of the building is not approved.

Top

Traffic Engineering 

Note: Supplementary Condition Completed (was Supplementary Condition Completed (was The applicant shall show the dimensions for proposed and existing parking stalls’ items, B = MIN. 9 FT, C = min. 18 ft, E = min. 24 ft, and F = min 20 ft, and degree of angle parking width and backing up, according to Figures II "Medium and Large Vehicles" parking design standards in Section 10.08(6)(b) 2. Signs and planting areas are to be excluded from the rectangular stall areas including the two (2) feet of vehicle overhang. The two (2) feet of vehicle overhang shall be shown on the plan and dimensioned. The applicant will need to submit 4 copies of supplemental drawing of A1 to Traffic Engineering. ))

Note: Supplementary Condition Completed (was Supplementary Condition Completed (was "Stop" signs shall be installed at a height of seven (7) feet at all driveway approaches behind the property line and noted on the plan. All directional/regulatory signage and pavement markings on the site shall be shown and noted on the plan. The applicant will need to submit 4 copies of supplemental drawing of A1 to Traffic Engineering. ))

Top

Zoning 

Note: All new signage and change of copy requires a permit. Applications can be found at: http://www.cityofmadison.com/BI/zoning.html#sign .

Note: Adherence to the landscape plan from 10/1989, on file with the City of Madison, is required. A site inspection will be conducted to ensure compliance.

Note: Supplementary Condition Completed (was At least one van accessible handicapped spot is required. A van accessible spot is a minimum 8' wide with a 8' wide access aisle. )

Note: Supplementary Condition Completed (was Two additional bike stalls are required. Stalls must be a minimum of 2’ X 6’ and have a 5’ access aisle. See http://www.cityofmadison.com/trafficEngineering/bicyclingParking.cfm for further specifications. Please note type of racks to be installed on plan.)

Note: Supplementary Condition Completed (was Accessible stalls must be marked with a sign at least 60" from grade. Please note location of signs on plan. )

Top