PROJECT 985:
5317 Old Middleton Rd
| Submitted by: | Grove Equity Investments |
| Project type: | Permitted Use |
| Description: | Parking Lot - Dumpsters |
| Status: | denied |
Resubmit will be accepted.
| Agency | Status | Requirements | Remarks | Checkout Date | Reviewed |
| Zoning | denied | 1 2 3 | | 1/14/2008 | 1/14/2008 |
| Traffic Engineering | denied | 1 2 3 4 5 | | 1/14/2008 | 1/15/2008 |
| Fire | approved | | | 1/14/2008 | 1/14/2008 |
| Engineering | supplement needed | 1 2 | | 1/14/2008 | 1/17/2008 |
| Lighting | supplement needed | 1 | | 1/14/2008 | 1/14/2008 |
| Engineering Mapping | denied | 1 2 | | 1/15/2008 | 1/16/2008 |
Engineering
Supplementary material required:
Submit PDF files of plan for Engineering records. Files can be emailed to Tim Troester at ttroester@cityofmadison.com. PDF's will need to match final plan submittal once redrafts are completed.
Supplementary material required:
Contact Tim Troester (ph 267-1995 or email ttroester@cityofmadison.com) to discuss possible erosion control and/or storm water management requirements. Phone number listed for developer contact returned a wrong number and no response was made to email sent by City Engineering. Additional requirements may be pending upon clarification of intended work and how much land area will be disturbed (if any).
Top
Engineering Mapping
Redraft required:
If a CAD file containing the required data cannot be supplied, then the site plan shall be revised to include all such data and the submittal of a redraft is required.
Supplementary material required:
The Applicant shall submit, prior to plan sign-off, a digital CAD file (single file) to the Engineering Program Specialist in the Engineering Division (Lori Zenchenko). The digital CAD file shall be to scale and represent final construction. The single CAD file submittal can be either AutoCAD (dwg), MicroStation (dgn) Version J or older, or Universal (dxf) format and contain an extraction of only the following data, each on a separate layer name/level number: a) Building Footprints b) Internal Walkway Areas c) Internal Site Parking Areas d) Other Miscellaneous Impervious Areas (i.e. gravel, crushed stone, bituminous/asphalt, concrete, etc.) e) Right-of-Way lines (public and private) f) Lot lines g) Lot numbers h) Lot/Plat dimensions i) Street names NOTE: Email file transmissions preferred lzenchenko@cityofmadison.com . Include the site address in the "Subject Line" of this transmittal.
Top
Lighting
Supplementary material required:
No lighting information was shown on the plan. Madison General Ordinance 10.085 requires residential parking to have a minimum of 0.25 and an average of 0.75 footcandles of light. Please submit one copy of the lighting plan with photometric information and a cutsheet of the light fixtures.
Top
Traffic Engineering
Redraft required:
The applicant shall provide scaled drawing at 1" = 20' or larger on one contiguous plan sheet showing all the facilities access, existing and proposed buildings, layouts of parking lots, loading areas, trees, signs, and vehicle movements, ingress/egress easements and approaches. The applicant shall include site plans for 5315 Old Middleton Rd. PUD (GDP-SIP) approved March 30, 2006 and show ingress/egress easement.
Redraft required:
When site plans are submitted for approval, the developer shall provide a recorded copy of the joint driveway ingress/egress and crossing easements.
Redraft required:
The parking facility shall be modified to provide for adequate internal circulation for vehicles. This can be accommodated by eliminating a parking stall at the dead ends. The eliminated stall shall be modified to provide a turn around area ten (10) to twelve (12) feet in width and signed “No Parking Anytime.”
Redraft required:
The applicant should show the dimensions for proposed and existing parking stalls’ items B, C, and E, for degree angle parking width and backing up, according to Figures II "Medium and Large Vehicles" parking design standards in Section 10.08(6)(b) 2.
Redraft required:
The driveway from the parking area behind the building to the street right-of-way for two-way operation shall be a minimum eighteen (18) ft in width according to M.G.O. 10.08(6)(a)4.
Top
Zoning
Redraft required:
Provide & sign handicap parking stalls. Handicapped parking stalls must be provided as close to entrance as possible.
Redraft required:
Show dimensions on parking stalls
Redraft required:
Provide bicycle parking facilities in accordance with Madison General Ordinances.